SNMP Monitoring Poller¶
Polls the network devices you list over SNMP v2c or v3 for interface counters, device health and reachability.
| Category | Infrastructure |
| Connector Name | signal-client.snmp-poll |
| Auth Method | SNMP v2c community, or SNMP v3 user (authPriv recommended) |
| Polling Interval | Per target: 60 s by default, 30 s minimum |
| Multi-Instance | Yes (up to 5) |
| Vendor Docs | RFC 3414: SNMPv3 User-based Security Model |
This connector polls devices. It is separate from the snmpd parser, which reads the log lines of the snmpd daemon sent over syslog. SNMPv1 is not supported.
Prerequisites¶
Vendor Requirements
Devices that answer SNMP v2c or v3, and access to their SNMP configuration.
- SNMP v2c or v3 enabled on each device
- For v3: a read-only SNMP user on each device
- Network: Conductor can reach each device on its SNMP port (UDP 161 by default)
Step 1: Create API Credentials¶
Create read-only SNMP credentials on each device. Use SNMP v3 with authPriv where the device supports it:
| Setting | Supported values |
|---|---|
| Security level | noAuthNoPriv, authNoPriv, authPriv |
| Authentication protocol | SHA, SHA-224, SHA-256, SHA-384, SHA-512 (MD5 is not offered) |
| Privacy protocol | AES, AES-192, AES-256 (DES is not offered) |
For SNMP v2c, set a read-only community string, and restrict which addresses may query the device to the Conductor's address.
Read-only access
The poller only reads. Give the user or community read-only access to the MIB views it needs, never write access.
Step 2: Configure in Conductor¶
- Open the Conductor UI at
https://<conductor-ip>/admin/settings/integrations - From the Add Integration dropdown, select SNMP Monitoring Poller
- Enter a unique name for this instance
-
For each device, fill in a target. Click Add Target to add another:
Field Value Description Host 192.0.2.10orswitch1.example.comIP address or DNS name only: no scheme, no :port, no credentialsPort 161SNMP port, 1–65535 SNMP Version v3v2corv3Community String (community) v2c only. Never logged Security Level authPrivv3 only Security Name (User) (user) v3 only Authentication Protocol SHA-256v3 with authNoPriv or authPriv Authentication Passphrase (passphrase) v3 with authNoPriv or authPriv. Never logged Privacy Protocol AES-256v3 with authPriv Privacy Passphrase (passphrase) v3 with authPriv. Never logged Poll Interval (seconds) 60Minimum 30. A lower value is raised to 30 Collect HOST-RESOURCES-MIB (CPU / memory / storage) Off Also read CPU load and memory use -
Toggle Enabled to on
- Click Save
An instance holds up to 512 targets.
Step 3: Validate Data Flow¶
After saving, verify the integration is working:
- Check connection status — The integration tile should show a green status indicator within 1–2 polling cycles
-
Check Signal Client logs. The poller writes one summary line per cycle:
-
Check artifacts in Analytics — Navigate to WitFoo Analytics Signals → Search and search for artifacts of stream
snmpand message typenetwork_monitor_event
What It Collects¶
| Group | Objects |
|---|---|
| SNMPv2-MIB | sysUpTime, sysName, sysDescr |
IF-MIB ifTable | Interface index, description, speed, admin and operational status, octets, errors and discards |
IF-MIB ifXTable (preferred) | Interface name, 64-bit octet counters, high speed, alias |
| HOST-RESOURCES-MIB (optional) | Processor load and memory use |
- Only interfaces that are administratively up are reported, up to 1,024 interfaces per device.
- The first poll after start-up reports status only: utilization needs two readings.
- When a device restarts, its counters start again and that poll reports status only.
- Monitoring polls never create work units.
Troubleshooting¶
Device Reported Down¶
- A device that does not answer is reported as
device_down. Reachability is data, not a pipeline error, so the other devices are still polled - Check that the Conductor can reach the device on its SNMP port
- Check the community string, or the v3 user, protocols and passphrases
Device Reported Degraded¶
- A device that answers the basic objects but fails an interface or host-resources walk is reported as
device_degraded, naming the part that failed. Check the device's SNMP view
No Utilization Values¶
- Utilization appears from the second poll onwards
- A device that reports no interface speed has no utilization percentage
No Data Appearing¶
- Confirm the integration shows Enabled in the Conductor UI
- If every target fails, the connector backs off: check the Conductor's route to the management network
- Check Signal Client logs:
docker logs signal-client-svc --tail=100