SNMP Monitoring Poller

Polls the network devices you list over SNMP v2c or v3 for interface counters, device health and reachability.

Category Infrastructure
Connector Name signal-client.snmp-poll
Auth Method SNMP v2c community, or SNMP v3 user (authPriv recommended)
Polling Interval Per target: 60 s by default, 30 s minimum
Multi-Instance Yes (up to 5)
Vendor Docs RFC 3414: SNMPv3 User-based Security Model

This connector polls devices. It is separate from the snmpd parser, which reads the log lines of the snmpd daemon sent over syslog. SNMPv1 is not supported.

Prerequisites

Vendor Requirements

Devices that answer SNMP v2c or v3, and access to their SNMP configuration.

  • SNMP v2c or v3 enabled on each device
  • For v3: a read-only SNMP user on each device
  • Network: Conductor can reach each device on its SNMP port (UDP 161 by default)

Step 1: Create API Credentials

Create read-only SNMP credentials on each device. Use SNMP v3 with authPriv where the device supports it:

Setting Supported values
Security level noAuthNoPriv, authNoPriv, authPriv
Authentication protocol SHA, SHA-224, SHA-256, SHA-384, SHA-512 (MD5 is not offered)
Privacy protocol AES, AES-192, AES-256 (DES is not offered)

For SNMP v2c, set a read-only community string, and restrict which addresses may query the device to the Conductor's address.

Read-only access

The poller only reads. Give the user or community read-only access to the MIB views it needs, never write access.

Step 2: Configure in Conductor

  1. Open the Conductor UI at https://<conductor-ip>/admin/settings/integrations
  2. From the Add Integration dropdown, select SNMP Monitoring Poller
  3. Enter a unique name for this instance
  4. For each device, fill in a target. Click Add Target to add another:

    Field Value Description
    Host 192.0.2.10 or switch1.example.com IP address or DNS name only: no scheme, no :port, no credentials
    Port 161 SNMP port, 1–65535
    SNMP Version v3 v2c or v3
    Community String (community) v2c only. Never logged
    Security Level authPriv v3 only
    Security Name (User) (user) v3 only
    Authentication Protocol SHA-256 v3 with authNoPriv or authPriv
    Authentication Passphrase (passphrase) v3 with authNoPriv or authPriv. Never logged
    Privacy Protocol AES-256 v3 with authPriv
    Privacy Passphrase (passphrase) v3 with authPriv. Never logged
    Poll Interval (seconds) 60 Minimum 30. A lower value is raised to 30
    Collect HOST-RESOURCES-MIB (CPU / memory / storage) Off Also read CPU load and memory use
  5. Toggle Enabled to on

  6. Click Save

An instance holds up to 512 targets.

Step 3: Validate Data Flow

After saving, verify the integration is working:

  1. Check connection status — The integration tile should show a green status indicator within 1–2 polling cycles
  2. Check Signal Client logs. The poller writes one summary line per cycle:

    docker logs signal-client-svc --tail=50 | grep -i "snmp"
    
  3. Check artifacts in Analytics — Navigate to WitFoo Analytics Signals → Search and search for artifacts of stream snmp and message type network_monitor_event

What It Collects

Group Objects
SNMPv2-MIB sysUpTime, sysName, sysDescr
IF-MIB ifTable Interface index, description, speed, admin and operational status, octets, errors and discards
IF-MIB ifXTable (preferred) Interface name, 64-bit octet counters, high speed, alias
HOST-RESOURCES-MIB (optional) Processor load and memory use
  • Only interfaces that are administratively up are reported, up to 1,024 interfaces per device.
  • The first poll after start-up reports status only: utilization needs two readings.
  • When a device restarts, its counters start again and that poll reports status only.
  • Monitoring polls never create work units.

Troubleshooting

Device Reported Down

  • A device that does not answer is reported as device_down. Reachability is data, not a pipeline error, so the other devices are still polled
  • Check that the Conductor can reach the device on its SNMP port
  • Check the community string, or the v3 user, protocols and passphrases

Device Reported Degraded

  • A device that answers the basic objects but fails an interface or host-resources walk is reported as device_degraded, naming the part that failed. Check the device's SNMP view

No Utilization Values

  • Utilization appears from the second poll onwards
  • A device that reports no interface speed has no utilization percentage

No Data Appearing

  • Confirm the integration shows Enabled in the Conductor UI
  • If every target fails, the connector backs off: check the Conductor's route to the management network
  • Check Signal Client logs: docker logs signal-client-svc --tail=100

See also: Integration Catalog · Integration Management · Signal Client · Common Troubleshooting