Skip to content

Conductor

Manage Conductor feeds, read Conductor integration health, and receive artifacts from Conductors.

Endpoints

Method Path Permission Description
GET /v1/conductor/feeds conductor:read or conductor:admin List the organization's Conductor feeds
GET /v1/conductor/feeds/status conductor:read or conductor:admin Whether feed registration is enabled, with total and pending counts
GET /v1/conductor/feeds/pending conductor:read or conductor:admin List pending feeds
PUT /v1/conductor/feeds/:id/approve conductor:admin Approve a pending feed
PUT /v1/conductor/feeds/:id/reject conductor:admin Reject a pending feed
DELETE /v1/conductor/feeds/:id conductor:admin Delete a feed
GET /v1/conductor/integrations/health Any signed-in user Health of the Conductor's integrations, relayed from the Conductor UI

An organization holds at most 1,000 pending feeds, and a pending feed expires after 7 days. A decision on a feed that has expired answers 404. See Integration Management.

Artifact Receiver

Conductors send artifacts directly to the Analytics artifact receiver (artifact-ingestion), not through the reverse proxy:

Method URL Authentication Description
POST https://<analytics-host>:8443/v1/conductor/artifacts/batch HMAC-SHA256 signature, checked when ANALYTICS_SECRET is set on the receiver Receive a batch of artifacts from a Conductor

On an AIO + Conductor appliance the local Conductor uses the internal port 8090. WFA sets the endpoint when it provisions the Conductor.

The /ingestion/ path is removed

The reverse proxy no longer serves the /ingestion/ path. A Conductor whose artifact endpoint was typed by hand with an /ingestion/ prefix now receives 404. Point it at https://<analytics-host>:8443/v1/conductor/artifacts/batch. Who may reach the receiver's ports (8090 and 8443) is decided by your firewall and network placement.

Limits

Limit Value
Artifacts in one batch 1,000. A larger batch is answered 400 with batch size exceeds maximum of 1000 artifacts
Largest artifact 9.5 MiB (9,961,472 bytes)
Request line and headers 12,288 bytes in all. Over it, the receiver answers 431
TLS port HTTP/1.1 only. A client that offers only HTTP/2 fails its handshake
Receiver busy 503 with Retry-After: 1. The exporter waits and sends again
Body over the limit 413

Proxy Routes

Conductor UI requests are proxied through the Analytics reverse proxy at /conductor/. JWT tokens are validated and mapped to Conductor roles via the ConductorAuth middleware.

Analytics Permission Conductor Role
conductor:admin Superuser
conductor:write Admin
conductor:read Staff

SAML Configuration Endpoints

These endpoints are available on the conductor-ui backend for SAML SSO configuration. They are served only by a Conductor node that serves its own sign-in page; behind an appliance's Analytics proxy, the Conductor UI does not mount its SAML wizard routes, which answer 404.

Method Path Permission Description
POST /api/auth/saml/test conductor:admin Test SAML configuration by validating IdP metadata and connectivity
POST /api/auth/saml/generate-keypair conductor:admin Generate a new SP (Service Provider) X.509 key pair for SAML signing

Test SAML Configuration

POST /api/auth/saml/test
Content-Type: application/json

{
  "idp_metadata_url": "https://idp.example.com/metadata",
  "entity_id": "https://analytics.example.com/saml/metadata"
}

Response (200):

{
  "success": true,
  "message": "SAML configuration is valid",
  "idp_entity_id": "https://idp.example.com",
  "sso_url": "https://idp.example.com/sso"
}

Generate SP Key Pair

POST /api/auth/saml/generate-keypair

Response (200):

{
  "certificate": "-----BEGIN CERTIFICATE-----\n...",
  "generated_at": "2026-03-12T00:00:00Z"
}

Note

The private key is stored server-side and encrypted with AUTH_CONFIG_ENCRYPTION_KEY. Only the public certificate is returned in the response.