Conductor¶
Conductor is WitFoo's signal pipeline for collecting, parsing, and exporting security logs to WitFoo Analytics.
Architecture¶
graph LR
S[Syslog/Beats/NetFlow Sources] --> SS[Signal Server]
V[Vendor APIs] --> SC[Signal Client]
SS --> SP[Signal Parser]
SC --> SP
SP --> AF[Artifact Filter]
AF --> AE[Artifact Exporter]
AE --> AI[Analytics Artifact Ingestion] Services¶
| Service | Port | Description |
|---|---|---|
| Signal Server | 514/udp, 514/tcp, 5044, 5045, 6514, 7514, 2055/udp | Receives syslog, Beats and NetFlow/IPFIX input |
| Signal Client | Internal | Polls vendor APIs (pull connectors) |
| Signal Parser | Internal | Parses raw signals into structured data |
| Artifact Filter | Internal | Filters and normalizes artifacts |
| Artifact Exporter | Internal | Sends artifacts to Analytics via HMAC-authenticated HTTP |
| Broker | 4223 | NATS JetStream for inter-service messaging |
On a WFA appliance running WFA 2.5.1 or later:
- The broker (4223) is published on
127.0.0.1only. - 2055/udp is published on Conductor and AIO + Conductor nodes and opened in the host firewall. The NetFlow/IPFIX listener stays off until you enable it under Log Servers in the Conductor UI. See Log Server Configuration.
The Conductor sends artifacts to the Analytics receiver at https://<analytics-host>:8443/v1/conductor/artifacts/batch, or the internal port 8090 on an AIO + Conductor appliance. See Conductor API.
HMAC Authentication¶
The Artifact Exporter authenticates with Analytics using HMAC-SHA256:
- Body hash:
hex(SHA256(body)) - Message:
timestamp + "." + bodyHash - Signature:
hex(HMAC-SHA256(secret, message))
Configured via ANALYTICS_SECRET on both Conductor and Analytics.
Management¶
Start/Stop¶
A Conductor appliance is managed with the WFA CLI:
See WFA CLI Reference.
Conductor UI¶
Access the Conductor UI through the Analytics reverse proxy. Requires conductor:read permission. The UI uses JWT auth bridge — Analytics JWT tokens are validated and mapped to Conductor roles.
On a standalone Conductor node, the Conductor UI serves its own sign-in page. From 1.2.0, its SAML sign-in signs in only accounts whose Auth Source is SAML (SSO). See User Management & Authentication.
Upgrading¶
Upgrade every Conductor, including separate or remote Conductor nodes, at the same time as Analytics or before it. A Conductor on 1.1.5 or older sending to 1.2.0 Analytics keeps only about one record per page or poll for several pull connectors. See Upgrading to 1.2.0.
Permissions¶
| Permission | Access Level |
|---|---|
conductor:read | View Conductor UI |
conductor:write | Configure Conductor |
conductor:admin | Full Conductor administration |